Intelligent Energy Management with Sigen Energy Gateway
When paired with SigenStor, the Sigen Energy Gateway offers advanced energy management and monitoring capabilities. It automatically detects power outages and ensures a seamless transition to backup power, maintaining supply during disruptions. Utilize the mySigen App to track energy usage and manage energy flows effortlessly, keeping you in control of your power needs at all times.
Seamless Backup Power Transition
Experience instant 0 ms switching to backup mode for worry-free energy usage during outages.
Fully compatible with generators, heat pumps, and other controllable load devices.
Offers versatile backup solutions, supporting both whole-home and partial-home backup configurations.
Provides 350 ms reverse power flow protection to safeguard both grid and generator connections.
Ensures an uninterrupted power supply whether through PV+ESS, grid, or generator integration, maintaining continuous energy access.
Available in: SP AU (Single Phase) and TP AU (Three Phase)
Light & Strong: Designed to Last
The Sigen Energy Gateway stands out with its full aluminum structure, a significant advancement over the commonly used galvanized steel in the industry. This design choice not only reduces the total weight by 8 kg but also extends the product's lifespan by a decade. Featuring anti-rust and corrosion-resistant properties, this super durable battery backup box excels in both aesthetics and practicality, ensuring longevity and efficiency.
More Connections: Always Ready
The Sigen Energy Gateway is equipped with six ports, designed to accommodate a variety of connections to meet every requirement. It offers the flexibility to connect up to three SigenStor energy storage systems and supports high-power devices like inverters, generators, heat pumps, or EV AC chargers, ensuring readiness for diverse energy needs.

Full Backup: Peace of Mind
The Sigen Energy Gateway ensures complete peace of mind, whether you require whole home or partial home backup. Capable of seamlessly switching to backup power during outages, it allows you to enjoy a 24/7 uninterrupted electricity supply. This robust system efficiently integrates power from multiple sources, including solar, grid, or generator, to ensure continuous energy availability in any situation.
Safe & Smart: Responsive and Reliable
The Sigen Energy Gateway excels in safety and intelligence, featuring:
Industry-leading 350 ms reverse power flow protection to safeguard against electrical backfeed.
Advanced system protection through a data-driven risk prevention mechanism, ensuring operational reliability.
Convenient monitoring and control of energy flow via the mySigen App, providing ease of use and real-time oversight.

Testimonials
What they are saying about us
F.A.Q
Frequently Asked Questions
-
I have single phase power, how much rooftop solar PV can I install on my roof?
If your house is single phase power, the amount of rooftop solar PV that you can install will depend on your electricity network provider, as each electricity network provider has different rules.
In almost all instances, you can install more inverter capacity than what the electricity network provider says, so long as you grid export limit your solar PV system. Note: Not all inverters have grid export limit capability.
Below is a table showing the allowed capacity (inverter capacity and your grid export limit), for each of the electricity network providers for single phase households:
SA Power Networks (SA) max 10kW inverter capacity, 5kW export limit Powercor (VIC) no inverter limit, 5kW export limit CitiPower (VIC) no inverter limit, 5kW export limit Ausnet Services (VIC) max 10kW inverter capacity, 5kW export limit United Energy (VIC) max 10kW inverter capacity, 10kW export limit Jemena (VIC) max 10kW inverter capacity, 10kW export limit Energex (QLD) max 10kW inverter capacity, 5kW export limit Ausgrid (NSW) max 10kW inverter capacity, 10kW export limit EVO Energy (ACT) max 10kW inverter capacity, 5kW export limit -
What are the benefits of rooftop solar power?
There are many benefits in installing a solar PV system including:
- Reduce or eliminate your power bill - you can regain control of your electricity costs.
- A revenue generating asset - you make back many times the initial cost of the system over the lifetime of your solar PV system.
- Add value to your home - a solar system adds value to your home increasing the resale value.
- Reduce your carbon footprint - a solar system generates no greenhouse gases while in operation giving you zero carbon power and lowing your overall carbon footprint.
- Reduce or eliminate your power bill - you can regain control of your electricity costs.
Light & Strong
The Sigen Energy Gateway, constructed from aluminum instead of the industry-standard galvanized steel, is 8 kg lighter and lasts a decade longer. This anti-rust, corrosion-resistant unit combines superior durability with aesthetic appeal. Features include:
Enhanced lightweight design
Practical and robust for varied environments
Exceptional durability for long-term reliability
Enhanced Connectivity
The Sigen Energy Gateway features six dedicated ports, accommodating up to three SigenStor energy storage systems and various high-power devices like inverters, generators, heat pumps, and EV AC chargers, ensuring versatile and expansive connection options.
Full Backup: Uninterrupted Power
The Sigen Energy Gateway ensures seamless power continuity for your entire home or specific areas. It instantly switches to backup power during outages, maintaining a 24/7 electricity supply from solar, grid, or generators.
Hybrid Power Sources: Leverages diverse energy sources for stability.
0 ms Load Side Disruption: Utilizes Sigenergy's patented technology for immediate power transition, guaranteeing no interruptions.
Sigen Energy Gateway for AU&NZ
Sigen Gateway | SP AU | TP AU | Units |
Grid Connection | |||
Grid connection type | Single phase | Three phase | |
Nominal AC input / output voltage | 220 / 230 / 240 | 380 / 400 | V |
Nominal AC input / output current | 54.6 | 91.2 | A |
Nominal AC input / output power | 12 | 60 | kW |
Nominal AC frequency | 50 / 60 | Hz | |
Disruption time of backup switch (This refers to the load-side disruption time, to achieve this functionality Sigen Energy Gateway needs to be used together with Sigen Energy Controller and Sigen Battery. Test conditions: In the open-circuit state of the power grid, the nominal power of the Sigen Energy Controller is higher than the total power of the backup loads) | 0 | ms | |
AC Output to Backup Port | |||
Nominal AC output voltage | 220 / 230 / 240 | 380 / 400 | V |
Nominal AC output current | 54.6 | 91.2 | A |
Nominal AC output power | 12 | 60 | kW |
Nominal AC frequency | 50 / 60 | Hz | |
Overvoltage category | III | ||
AC Output to Non-Backup Port | |||
Nominal AC output voltage | 220 / 230 / 240 | - | V |
Nominal AC output current | 54.6 | - | A |
Nominal AC output power | 12 | - | kW |
Nominal AC frequency | 50 / 60 | - | Hz |
Inverter Connection | |||
Nominal AC voltage | 220 / 230 / 240 | 380 / 400 | V |
Nominal AC input current | 54.6 (INV1), 32 (INV2) (For Sigenergy single phase inverter products, 8.0-12.0 kW inverters should be connected to the INV1 port, 3.0-6.0 kW inverters should be connected to the INV2 port. The sum of the parallel power of the Sigenergy inverters cannot exceed 12 kW.) | 45.6 (INV1), 45.6 (INV2), 30 (INV3) (For Sigenergy three phase inverter products, the INV1 and INV2 ports support 17.0-30.0 kW inverter, the INV3 port supports 5.0-15.0 kW inverter. The sum of the parallel power of the Sigenergy inverters cannot exceed 60 kW.) | A |
Compatible EV charger power | 7 | 11 / 22 | kW |
Smart Port Connection | |||
Generator output voltage | 220 / 230 / 240 | 380 / 400 | V |
Nominal input / output current | 54.6 | 91.2 | A |
Nominal AC input / output power | 12 | 60 | kW |
Generator 2-wire start | Supported | ||
General Data | |||
Dimensions (W / H / D) | 495 / 370 / 165 | 510 / 750 / 179 | mm |
Weight | 9.5 | 25 | kg |
Storage temperature range | -40 ~ 70 | °C | |
Operating temperature range | -30 ~ 55 | °C | |
Relative humidity range | 0% ~ 95% | ||
Max. operation altitude | 4000 | m | |
Cooling | Natural convection | ||
Ingress protection rating | IP54 | ||
Communication | Fast Ethernet , RS485, dry contact | ||
Installation method | Wall mounted |
To ensure the long-term operating of the equipment, you are advised to perform routine maintenance according to this section.
! DANGERTo remove the inner panel, ask a professional for evaluation before proceeding. |
Inspection Items | Inspection Method | Power Off or Not | Maintenance Interval |
System cleaning | Check the device regularly for shielding and dirt. If so, clean it up. Do not use tools that may cause electric shock or insulation damage, such as wire brushes and during the cleaning process. | Yes | Once every 3 months |
System operating state |
| No | Once every 6 months |
Electrical connection |
| Yes | Check once every 6 months after creating new systems and once every 6 to 12 months thereafter. |
Grounding reliability | Check whether the ground cable is properly and reliably connected. | No | Check once every 6 months after creating new systems and once every 6 to 12 months thereafter. |