iStore 270L R290 Heat Pump Install Manual v1.4 Jan2025

Description

Pre-installation checklist

 

Circuit Selection

  • Avoid installing the iStore onto a Controlled Load / Offpeak circuit unless the circuit provides for manual activation of the circuit – no service can be provided without business hours power supply.

Cable Connection

  • This unit requires an isolating switch as required by local by laws

  • If the power cord is damaged, it must be replaced by a qualified electrician

  • Local codes including but not limited to AS/NZS 3000 must be adhered to for all electrical work and be undertaken by a licensed electrician. The licensed electrician deems the circuit is suitable. Adequate overload protection and a residual current device of appropriate size should be installed.

  • If the iStore is rated below 10amps and is fitted with a 3 pin plug the electrician may remove the plug if required without effecting the warranty.

  • Allow 1m of free cable outside the iStore to avoid noise transfer to the wall and facilitate ease of servicing.

Tank Location

  • Place tank on level surface and in accordance with building and plumbing codes.

  • To avoid noise transfer:-

    • Do NOT have the iStore touching the wall, 50mm clearance minimum is required.

    • Do NOT have solid electrical conduit attached to the iStore – leave 1m of free coiled flex cable.

    • Do NOT leave pipework loose.

  • Consider tank location to reduce any nuisance noise complaints (eg positioning near bedrooms or neighbours’ bedrooms)

  • Avoid positions where leaf litter and soil can build up in and around the unit.

  • Avoid positions where excessive pollen may be sucked into the unit.

  • Ensure the minimum space between the unit and walls and objects are per specifications illustrated in Diagram 1a/2a and Diagram 1b/2b.

  • Unit shall be located as close as possible to the most frequently used hot water outlet.

Seismic Restraints

  • Where required the unit must be braced with with seismic restraints according to local standards

  • Only applicable in earth-quake zones

Air Flow

  • The iStore requires a minimum of 120 cubic meters of natural ventilation to operate efficiently

  • An example would be an area of 8.0m x 6.3m x 2.4m (a large double garage or open space under a home)

  • If suitable air flow or area cannot be provided then the performance may be reduced

  • External installation is the preferred method to capture the warm ambient air temperature Air discharge will always be cold

  • If unit is being installed internally, provision for fresh air to be introduced shall be provided 450 m3/h minimum requirement


loading
1300 86 78 73
Reviews
Products Review Pure-Electric

Product Review Rating

5.0
Based on 80 reviews
Google Review Pure-Electric

Google Review Rating

4.9
Based on 84 reviews
Trustpilot Review Pure-Electric

Trustpilot Rating

4.9
Based on 111 reviews
Wordofmouth Review Pure-Electric

Word of Mouth Rating

5.0
Based on 16 reviews
Facebook Review Pure-Electric

Facebook Rating

5.0
Based on 9 reviews